Public View
Back to Dashboard
Class Code Information
Phraseology
Scaffolds – Sidewalk Bridges – Not Over One Story in Height – Installation, Repair or Removal – All Operations to Completion & DriversNot applicable to contractors who erect, repair or remove sidewalk bridges as an incidental part of their construction work.
Description
Code 9527 applies to employers engaged in erecting sidewalk bridges for general contractors. The employer delivers the necessary materials such as pipes, wood planks or aluminum sheets. Pipes are assembled with bolts and pins to create the framework of the sidewalk bridge. The wood planks or aluminum sheets are placed and secured to the framework to form the bridge walkway over pedestrian sidewalk traffic. The height of the sidewalk bridges cannot be higher than one story in height. The employer conducts safety checks to ensure compliance with state safety codes. The employer dismantles the scaffolding when the construction operation is finished, and it is delivered back to the employer’s yard for storage and repair, if necessary. This classification is also applicable to interior or exterior erection.
Assignment by Analogy
No InformationOperations to be Separately Rated
- Installation:
- Outrigger scaffolding. Refer to Code 5403 “Carpentry – NOC – All Operations to Completion.”
- Scaffolds, hod hoists, and construction elevators. Refer to Code 9526 “Scaffolds, Hod Hoists or Construction Elevators – Built-Up From the Ground – Installation, Repair or Removal – All Operations to Completion & Drivers.”
- Suspended or swing scaffolding. Refer to Code 9534 “Mobile Crane and Hoisting Service Contractors – NOC – All Operations to Completion & Drivers.”